Maintenance Objects
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
Table 581. TEST #52 Control Channel Loop Around Test
Error
Code
Test Result
none or
ABORT
2100
FAIL
PASS
any
NO BOARD
1920
Issue 5 October 2002
Description/ Recommendation
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The test failed because the circuit pack failed to return the circuit pack
code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset board, and
release busy board commands, and then retest.
3. If the problem continues, replace the circuit pack.
4. Run the test again.
Communication with this circuit pack is successful.
This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there
is some inconsistency between the physical configuration and the data
kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at 1-minute intervals for a maximum of 5 times.