Avaya DEFINITY Server CSI Maintenance Manual page 1917

Table of Contents

Advertisement

XXX-BD (Common Port Circuit Pack)
NPE Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for all the Network Processing Elements (NPEs)
on the circuit pack.
Table 579. TEST #50 NPE Audit Test
Error
Code
Test Result
none or
ABORT
2100
1019
ABORT
FAIL
PASS
EXTRA BD
any
NO BOARD
555-233-119
Description/ Recommendation
System resources required for this test are not available.
Test already in progress.
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The circuit pack's NPEs have been updated with their translation.
Certain circuit packs have limitations on how many circuit packs can
be in the system such as the Call Classifier (TN744). The Call
Classifier allow only 10 circuit packs in each system. All additional
circuit packs return EXTRA-BD and should be removed.
This is normal if the test is being done when (a) the circuit pack is
not physically in the system or (b) the system is booting up.
Otherwise, there is some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5
times.
Continued on next page
Issue 5 October 2002
1917

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents