VC-DSPPT
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the
reset procedure, the VC-DSPPT will execute a series of self- tests on the
hardware. If these self- tests fail, the test will fail; otherwise the test will pass.
Before executing the test, the VC-DSPPT must be busied out by executing the
busy port PCSSpp command. After the completion of the test, the VC-DSPPT
must be released by executing the release port PCSSpp command.
Table 569. TEST #1106 VC Port Reset DSP Test
Error
Test
Code
Result
1000
ABORT
1015
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
FAIL
PASS
555-233-119
Description/Recommendation
System resources required to run this test are not available, or the port may
be busy with a call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The VC-DSPPT is not busied out.
1. Busy out the VC-DSPPT by executing the busy port PCSSpp command
and then retry the test.
Response to the test was not received from the VC-DSPPT within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this result occurs again, replace the circuit pack.
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Could not allocate the necessary resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
The VC-DSPPT was successfully reset.
1. Release the VC-DSPPT by executing the reset port PCSSpp
command.
Continued on next page