Avaya DEFINITY Server CSI Maintenance Manual page 1903

Table of Contents

Advertisement

VC-SUMPT
Table 573. TEST #1100 VC Summer Port Local TDM Loopback Test
Error
Test
Code
Result
1000
ABORT
1002
ABORT
1003
ABORT
1004
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
2103
ABORT
0
FAIL
1
FAIL
PASS
555-233-119
Description/Recommendation
System resources required to run this test are not available, or the port may
be busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The system could not allocate time slots for the test. The traffic load on the
system is very high or time slots are out-of-service due to TDM-BUS errors.
Refer to
''TDM-BUS (TDM Bus)''
any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
The system could not allocate a Tone Detector for the test, the system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any
''TTR-LEV (TTR Level)''
2. Resolve any
''TONE-PT (Tone Generator)''
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of 5 times.
The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port to determine whether the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Response to the test request was not received from the VC-BD circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports
are not in use. Reset the circuit pack by issuing the busyout board
PCSS and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
Internal system error
Could not allocate the necessary system resources to run this test.
The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The TDM Loop Around Test failed.
The Conference Circuit Test failed.
1. Replace circuit pack.
The VC Summer Port Local TDM Loopback Test passed.
maintenance documentation to diagnose
errors.
errors.