Avaya DEFINITY Server CSI Maintenance Manual page 1863

Table of Contents

Advertisement

VAL-BD (Voice Announcements over LAN Circuit Pack)
g. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms can be present:
If Error Type 3999:
Does not accompany
Error Type 3586,
Does not accompany
Error Type 3586,
Accompanies Error
Type 3586,
1. Busyout (busyout board UUCSS) and release (release board
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal
h. Error Type 3840: Circuit pack received bad control channel message from
switch.
Aux Data:
4096
4097
4098
4099
4100
4101
4102
555-233-119
Circuit pack port tests return NO BOARD.
List configuration command shows circuit pack and ports are
installed properly
And traffic
volume is:
Heavy
Light
Either Light or
Heavy
UUCSS) the circuit pack.
board UUCSS), reset (reset board UUCSS), and release (release
board UUCSS) the circuit pack.
escalation procedures.
Bad major heading
Bad port number
Bad data
Bad sub-qualifier
State inconsistency
Bad logical link
Bad application identifier
Then:
Circuit pack is in service, but sent
at least half hyperactive
threshold. With heavy traffic, this
is normal.
Circuit pack is in service, but sent
at least half hyperactive
threshold. With light traffic, this
error indicates a problem with the
circuit pack, its links, or the
equipment attached to the links.
Switch removed hyperactive
circuit pack.
Issue 5 October 2002
1863

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents