XXX-BD (Common Port Circuit Pack)
Table 580. TEST #51 Ringing Application Circuit Test — Continued
Error
Test
Code
Result
FAIL
PASS
any
NO
BOARD
555-233-119
Description/ Recommendation
No ringing current is detected. The ringing application circuitry on this
circuit pack probably is not healthy.
1. Retry the command again.
2. If the test continues to fail, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, refer to the RING-GEN Maintenance
documentation and try to resolve any problem(s).
b. If there are no RING-GEN errors, replace the circuit pack.
3. Retry the command again.
Ringing current is detected or this vintage of the Analog Line circuit pack
does not support the Ringing Application Circuit Test. Analog Line circuit
packs that DO NOT support Test #51 include TN742 Vintage 3 and earlier.
This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there is
some inconsistency between the physical configuration and the data kept in
the system.
1. Verify that the circuit pack is physically in the system. Verify that the
system is not in a stage of booting up. Retry the command at 1-minute
intervals for a maximum of 5 times.
Continued on next page
Issue 5 October 2002
1919