Avaya DEFINITY Server CSI Maintenance Manual page 1914

Table of Contents

Advertisement

Maintenance Objects
Hardware Error Log Entries and Test to Clear
Values
Common Port Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
1
0
0
1(a)
0
18(b)
0
23(c)
0
125 (d)
257
65535
257 (e)
Any
267 (d)
0
513 (f)
Any
769 (g)
4358
1025 (h)
4363
1281 (i)
1538 (j)
Any
1793 (k)
3840 (l)
Any
3999 (m)
Any
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system. This error type is not applicable to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
1914
Issue 5 October 2002
Associated Test
Alarm Level
Any
Any
Circuit pack removed
MINOR
or SAKI Sanity Test
(#53)
busyout board PCSS
WARNING
None
WARNING
None
MINOR
Control Channel
MINOR
Test (#52)
None
None
WARNING
None
MINOR
None
NPE Audit Test
(#50)
Ringing Application
MINOR
Test (#51)
None
WARNING/
MINOR
Neon Test (#220)
MINOR
None
None
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity Test (#53) fails.
On/Off
Board
Test to Clear Value
Any
test board PCSS sh r 1
ON
OFF
release board PCSS
OFF
ON
ON
test board PCSS sh r 20
ON
ON
test board PCSS sh
test board PCSS l r 20
ON
test board PCSS r 2
ON
ON
test board PCSS r 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents