Avaya DEFINITY Server CSI Maintenance Manual page 1867

Table of Contents

Advertisement

VAL-BD (Voice Announcements over LAN Circuit Pack)
PPE/LANBIC Receive Parity Error Counter Test
(#595)
This test is non-destructive. When the VAL circuit pack detects a parity error with
a received frame, it increments the PPE/LANBIC Receive Parity error counter.
This test reads and clears the counter, and can verify repair of the problem.
Errors can indicate a problem with:
This circuit pack
A packet bus
Another circuit pack on the bus
Table 552. TEST #595 PPE/LANBIC Receive Parity Error Counter Test
Error
Test
Code
Result
2000
ABORT
2100
ABORT
2500
ABORT
1-10
FAIL
PASS
555-233-119
Description/ Recommendation
Did not receive circuit pack test response within the allowable time period.
Retry command at 1-minute intervals, up to 5 times.
If the problem persists, reset the circuit pack (reset board UUCSS).
If the problem persists, replace the circuit pack.
Could not allocate the necessary system resources to run test.
Internal system error.
Retry the command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
Circuit pack detects parity errors. The Error Code indicates the value of the
on-board error counter.
Retry the command at 1-minute intervals, up to 5 times.
If the test continues to fail, execute the Packet Interface Test (#598) (test
board UUCSS).
If Packet Interface Test (#598) fails, see repair procedures for Test (#598).
Circuit pack detects no errors.
Continued on next page
Issue 5 October 2002