Avaya DEFINITY Server CSI Maintenance Manual page 1923

Table of Contents

Advertisement

XXX-BD (Common Port Circuit Pack)
Table 583. TEST #220 Neon Test — Continued
Error
Test
Code
Result
1018
ABORT
2000
ABORT
2100
ABORT
ABORT
FAIL
555-233-119
Description/ Recommendation
There are not any translated ports on the circuit pack, or if there are ports,
then none are administered to have "neon."
1. Verify that there are ports administered on the circuit pack. If no ports
are administered, no further action is required.
2. Verify that you have neon sets connected (sets that may be neon sets
are 500 and 2500 series, also some non-Avaya may also be neon
sets). If no neon sets are connected to the circuit pack, the test
continues to abort, but no further action is required.
3. If there are no neon sets connected to the circuit pack, at least one port
needs to be translated with neon. To check if a port is translated with
neon, use the display port PCSSpp command to determine the
station extension of any station on this circuit pack. Use the display
station <extension> to determine if the port is administered with neon.
The field "Message Waiting Indicator:" must be set to "neon" for at least
one of the administered ports. If this field is not administered to "neon"
the test continues to abort. This is acceptable because not all stations
have neon lamps on their analog terminals. If none of the terminals
have neon lamps, the test continues to abort, but no further action is
required.
4. Retry the command again.
5. Retry the command at 1-minute intervals a maximum of 5 times.
6. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for this test on other circuit packs as
well, then the ringing generator may be defective. If it does not occur
on port test 48 for ANL-16-L, all four ring phases are in use.
7. Retry the command again.
Response to the request was not received within the allowable time period.
Could not allocate the necessary system resources to run this test.
Could not allocate the necessary system resources to run this test. Internal
System Error.
1. If Error Type 1538 is present in the Error Log, follow the recommended
maintenance strategy.
The test failed because no neon current was detected.
1. Look for the failure of test 220. If test 220 fails, replace the 650A power
supply.
2. Retry the command again.
Continued on next page
Issue 5 October 2002
1923