VC-SUMPT
Table 572. TEST #6 NPE Crosstalk Test
Error
Test
Code
Result
1000
ABORT
2012
ABORT
2100
ABORT
FAIL
PASS
VC Summer Port Local TDM Loopback
Test (#1100)
This test is destructive.
This test verifies the connectivity of a VC Summer Port across the TDM bus. It
aborts if calls associated with the port are in progress. Failure of this test indicates
an on-board fault associated with the port hardware on the circuit pack. The
Loopback Test runs the following tests (refer to
A Looparound test across the TDM bus.
A conference circuit test.
The tests are run in the above order. If the first test fails, the switch returns an
error code, and the second test is not executed.
555-233-119
Description/Recommendation
System resources required to run this test are not available. The port may
be busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Internal system error
Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
The NPE of the tested port was transmitting in error, causing noisy and
unreliable connections.
1. Replace the circuit pack.
The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test a
maximum of 10 times.
2. If complaints still persist, examine the station, connections, and wiring.
Continued on next page
Figure 65 on page
1902):
Issue 5 October 2002
1901

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF