Maintenance Objects
Error Log Entries and Test to Clear Value
Table 560. VAL-PT Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
SCOTCH Sync
Looparound Test
(#1275)
257 (b)
0
3585 (c)
0-1
TDM Looparound
Test (#1285)
1.
There is no short test sequence for this MO. All tests are available in the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
b. Error Type 257: VAL port detected overrun or underrun condition that can
indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 3585: TDM Port Looparound Test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. Refer to TDM Looparound Test (#1285) repair procedure.
1880
Issue 5 October 2002
Alarm
Level
Any
MINOR
WARNING
MAJOR
procedures.
procedures to verify repair.
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp l
ON
test port UUCSSpp l r 3
OFF
ON
test port UUCSSpp l r 3
Continued on next page