Maintenance Objects
Table 562. TEST #1285 TDM Looparound Test
Error
Test
Code
Result
1000
ABORT
1002
ABORT
1003
ABORT
2000
ABORT
2012
ABORT
2100
ABORT
FAIL
PASS
1882
Issue 5 October 2002
Description/ Recommendation
The port is in use.
Retry the command when the port is idle. You can force the port to the idle
state with the busyout port UUCSS command.
Escalate if the problem persists.
This command is destructive, tearing down all calls and links using the port.
No TDM bus timeslots available for the test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
No more tone receivers idle for use in this test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
Did not receive circuit pack test response within the allowable time period.
If this problem persists, reset the circuit pack (busyout board UUCSS, reset
board UUCSS, and release board UUCSS).
Repeat the test.
If the problem persists, replace the circuit pack.
Internal system error.
Retry the command at 1-minute intervals, up to 3 times.
Escalate if the problem persists.
Could not allocate the necessary system resources to run test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
Received tones do not match transmitted tones.
Retry command at 1-minute intervals, up to 3 times.
If the problem persists, refer to TDM-BUS, Tone Generator, and Tone
Receiver repair procedures.
If the problem persists, reset the board (busyout board UUCSS, reset
board UUCSS, and release board UUCSS). Repeat the test.
If the problem persists, replace the circuit pack.
Port connections across the TDM bus function properly.
Continued on next page