Sign In
Upload
Manuals
Brands
Alcatel-Lucent Manuals
Switch
1850 TSS-60
Alcatel-Lucent 1850 TSS-60 Manuals
Manuals and User Guides for Alcatel-Lucent 1850 TSS-60. We have
1
Alcatel-Lucent 1850 TSS-60 manual available for free PDF download: Installation And System Turn-Up Manual
Alcatel-Lucent 1850 TSS-60 Installation And System Turn-Up Manual (386 pages)
Transport Service Switch
Brand:
Alcatel-Lucent
| Category:
Switch
| Size: 12 MB
Table of Contents
Table of Contents
3
About this Document
11
Purpose
11
Reason for Reissue
11
Intended Audience
11
How to Use this Document
12
Cable and Fiber Installation
12
Safety Information
14
Conventions Used
15
Related Information
15
Document Support
16
Technical Support
16
How to Order
16
How to Comment
16
Packaging Collection and Recovery Requirements
17
Recycling/Take-Back/Disposal of Product
17
Safety
20
Safety
21
Safety Laser Safety
22
Electrostatic Discharge ESD Considerations
23
Static Control Wrist Strap
23
Laser Product Classification
28
Laser Classes
29
Alcatel-Lucent 1850 TSS-60 Optical Specifications
30
Alcatel-Lucent 1850 TSS-60 Optical Circuit Pack Laser Safety Specifications
30
Alcatel-Lucent 1850 TSS-60 Optical PTM Laser Safety Specifications
31
Dispersion-Limited Receiver Sensitivity for OC-192 DWDM Ptms
38
Part I: Physical and Power Installation
40
Physical Installation
47
Physical Installation
48
Physical Installation Planning
50
Shelf Mount Rear Cover Kit 849001367
50
Bay Mount Rear Cover Kit 849001060
51
Cable Requirements and Options
51
Inspection
52
Alcatel-Lucent 1850 TSS-60 Center Divider
53
Center Divider
54
Alcatel-Lucent 1850 TSS-60 Shelf Installation
56
Alcatel-Lucent 1850 TSS-60 Mounting Bracket Positions - 23-Inch/19-Inch Frame
58
Fiber Duct Mounting
59
Safety Ground Screw
60
Fiber Spools
61
Heat Baffle
62
Power Cable Installation
63
Power Connection
63
Power Cable Assemblies
65
Power Connections
65
Final Operations
66
Cable and Fiber Installation
67
Planning
69
Cable Requirements and Options
70
Connector References
72
Connector Types and Pinouts
72
Inspection
73
DS1/EI Cable Installation
74
DS1/E1 Cable Assemblies
74
DS1/E1 Cable Connectors
75
DS1/E1 Cable Routing to the Right
76
DS1/E1 Cable Routing to the Left
76
DS1/E1 Transmission Connections
79
DS3/EC-1 Cable Installation
82
DS3/EC-1 Cable Connections
83
DS3/EC-1 Cable Routing to the Right
84
DS3/EC-1 Cable Routing to the Left
85
DS3/EC-1 Cable Assemblies
86
Twenty-Four Cable DS3/EC-1 Transmission Connections
95
Twelve Cable DS3/EC-1 Transmission Connections
99
DS1 and DS3 Hybrid Cable Installation
101
DS1 and DS3 Hybrid Cable Connections
102
DS1 and DS3 Hybrid Cable Routing
102
DS1 and DS3 Hybrid Cable Assemblies
104
DS1 and DS3 Hybrid Cable DS3 Transmission Connections
107
DS1 and DS3 Hybrid Cable DS1 Transmission Connections
107
10/100BASE-T Ethernet Cable Installation
108
10/100Baset Ethernet Connections
110
IAO LAN and TCP/IP Cable Installation
112
IAO LAN/TCP-IP Cable Connection to Rear of Alcatel-Lucent 1850 TSS-60
113
LAN 10Baset Cable Assemblies
113
LAN 10Base-T Cross-Over Cable Connections
115
LAN 10Base-T Straight-Through Cable Connections
115
Modem Cable Installation
116
Modem Cable Connection
116
Modem Cable Assemblies
116
Modem Cable Connections
117
Sync Cable Installation
118
Synchronization Cable Assemblies (SYNC1 and SYNC2)
118
Sync Cable Connections
119
Synchronization Cable (DS1 Timing Reference) Connections
122
Office Alarm Cable Installation
123
Office Alarm Cable Assemblies
123
Office Alarm Cable Connections
124
Office Alarm Cable Routing
124
Alarm Office Connections
126
Miscellaneous (Environmental) Discrete Telemetry Cable Installation
127
Miscellaneous Discrete Cable Connection
128
Miscellaneous Discrete Cable Routing
128
Miscellaneous Discrete Cable Assemblies
130
Miscellaneous (Environmental) Discrete Telemetry Connections
130
OC-3/OC-12/OC-48/OC-192 Main Optical Fiber Cable Installation
132
Optical Fiber Routing
133
OC-3/OC-12/OC-48 Low-Speed Optical Fiber Cable Installation
135
100/1000BASE-X Optical Fiber Cable Installation
137
CIT (RS-232) Cable Installation
139
CIT Cable Assembly
139
Standard CIT Cable Connection
140
Final Operations
141
Circuit Pack Installation
143
Circuit Pack Installation
144
Description
144
Powering
145
Circuit Pack Installation
145
Alcatel-Lucent 1850 TSS-60 Shelf Power Supply Requirements
145
Power Connections on Alcatel-Lucent 1850 TSS-60 Backplane
146
Circuit Pack Compatibility
149
Release 2.0 Circuit Pack Slot Compatibility
149
Alcatel-Lucent 1850 TSS-60 Shelf
151
Initial Circuit Pack Installation
152
Part II: Stand-Alone Installation Testing
175
Stand-Alone Node Setup
182
Software Installation
183
Circuit Pack Installation
184
Use of Wavestar ® CIT Software
188
Circuit Pack Program Version Verification
192
Alcatel-Lucent 1850 TSS-60 Shelf Initialization
194
Stand-Alone Installation Testing
195
Stand-Alone Installation Testing
199
LBO Software Settings
199
Clearing Alarms
202
Local Equipment and Cross-Connect Tests
204
DS1/E1 Testing
205
DS3/EC1 Testing
211
LNW74 and LNW66 Testing
218
OC-3 Low-Speed Testing
222
OC-12 Low-Speed Testing
227
OC-48 Low-Speed Testing
230
LED Test
235
Office Alarm Test
237
Office Alarm Connections
238
Automatic Protection Switching and Alarm Test
242
Manual Switching Tests
246
External Timing Verification
250
Alcatel-Lucent 1850 TSS-60 Shelf Backplane
252
Miscellaneous (Environmental) Discrete Telemetry Test
253
Miscellaneous (Environmental) Discrete Functions
254
Miscellaneous (Environmental) Discrete Telemetry Connections
255
Modem Connection Test
256
Final Operations
259
Part III: Network Turn-Up and Testing
261
Connecting Adjacent Network Elements
266
Connecting Adjacent Network Elements Fiber Installation
269
Attenuation Table
271
Optical Transmission Test (OC-192, OC-48, OC-12, OC-3)
275
Automatic Protection Switching Test
277
Manual Switching Tests
279
Final Operations
282
WDMX Setup and Testing: Integration Procedures
286
WDMX Setup and Testing: Integration Procedures
287
Turn-Up and Test the LNW785 8 Channel OMD
288
Connecting the Ring (Mains) to the WDMX
290
Removing Provisioning and Equipage from the LNW785
293
Channel/Port Assignments
295
Attenuation Table
295
Part IV: Miscellaneous Detailed Installation Procedure and Reference Material
297
Technical Support
297
Fiber Cleaning
297
Technical Assistance
300
Accessing and Navigating the On-Line Customer Support (OLCS) Web Site
305
Other Technical Support Services
310
B Fiber Cleaning
313
Fiber Cleaning
314
Equipment Requirements and Recommendations
315
Required and Recommended Equipment and Materials
315
Safety Instructions
316
Cleaning/Inspecting Optical Connectors
317
Cleaning the Ferrule Endface
318
Cletop Cleaner
319
Acceptability Criteria for Fiber Cleaning
321
Cleaning Pluggable Optics Module
323
CPTM Installation
325
PTM Modules
326
Alcatel-Lucent Approved Ptms
326
Install Pluggable Modules
329
Pluggable Optics Module
329
PTM Installation
329
Module Types
330
Electrical PTM Routing
335
D Installing Fiber Connectors and Lbos
337
Lbos
338
LC-Type Connector Ports on Circuit Pack
338
LC-Type LBO
339
LC-Type LBO Inserted into LC-Type Connector Port
339
Removing LC-Type LBO from LC-Type Connector Port
340
Fiber Connections
341
LC-Type Fiber Connector
341
LC-Type Fiber Connection
342
E Backplane Pin Replacement
343
Pin and Connector Background
344
Backplane Locations of METRAL™ Pins
345
Repair Kits and Tools
346
Metral™ Pins
346
Simple Repair Methods
347
Replacement Methods
349
F Fiber Labeling
351
Fiber Description
352
Fiber Labels
354
Advertisement
Advertisement
Related Products
Alcatel-Lucent 1850 TSS-100
Alcatel-Lucent 1850 TSS-160
Alcatel-Lucent 1850 TSS-320
Alcatel-Lucent 1850 TSS-5
Alcatel-Lucent 1850
Alcatel-Lucent 1850 320
Alcatel-Lucent 1830 PSS-36
Alcatel-Lucent 1830 PSS-16
Alcatel-Lucent 1830 PSS-32
Alcatel-Lucent 1830 PSS-4
Alcatel-Lucent Categories
Switch
IP Phone
Telephone
Network Router
Network Hardware
More Alcatel-Lucent Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL