GE Healthcare
Revision 1
Code
Category
132/037
DEBUG
ONLY
132/038
DEBUG
ONLY
132/039
DEBUG
ONLY
132/040
DEBUG
ONLY
132/041
DEBUG
ONLY
132/042
DEBUG
ONLY
132/043
DEBUG
ONLY
132/044
DEBUG
ONLY
132/045
DEBUG
ONLY
132/046
DEBUG
ONLY
132/047
DEBUG
ONLY
132/048
DEBUG
ONLY
132/049
DEBUG
ONLY
132/050
DEBUG
ONLY
ERR-SUB-A-003.fm
Text in Log File or
on LCD
TILT INVALID
STOP_MOTION_DS
P_ACTIVE ERROR
TILT INVALID
STOP_MOTION_LIN
E_ACTIVE ERROR
TILT INVALID
BRAKE_MALFUNCT
ION ERROR
TILT INVALID
CLUTCH_MALFUN
CTION ERROR
TILT INVALID
CODER_SEQUENC
E_ERROR
TILT INVALID
CODER_SIGNAL_E
RROR
TILT INVALID
USERINTERFACE_
ERROR
TILT INVALID
COLLIMATOR_BUT
TON_ERROR
TILT INVALID
RELAY_ERROR
TILT INVALID
CORELLATION_ER
ROR
TILT INVALID
UPPER_OPTICAL_
FORK_REACHED
ERROR
TILT INVALID
LOWER_OPTICAL_
FORK_REACHED
ERROR
TILT INVALID
FORCE_SENSOR_
DEFECT ERROR
TILT INVALID
UNCONTROLLED_
MOTION ERROR
Service Information and Procedures Class A 2385072-16-8EN
Possible Cause/Recommended Action
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Ignore this error. If the problem persists, contact your
OLC.
Page no. 897
ERR SUB A003 - Gantry Error Messages
Senographe DS
Job Card
Chapter 9
Need help?
Do you have a question about the Senographe DS and is the answer not in the manual?
Questions and answers
G.E.Essential l have recently bought What is the full weight.of the mamo Full weight of the console and other İtem's also measurements of each item with the main machine please All this Shipping Company required
The GE Senographe DS mammography machine is shipped in three crates with the following dimensions and weights:
- Crate 1 (Gantry, Generator Cabinet, and ramp):
- Dimensions: 2066 mm (81.34 in) depth × 848 mm (33.39 in) width × 2292 mm (90.24 in) height
- Mass: 641 kg (1410.2 lbs)
- Crate 2 (Control Station):
- Dimensions: 1110 mm (43.70 in) depth × 770 mm (30.31 in) width × 1850 mm (72.83 in) height
- Mass: 210.5 kg (464.07 lbs) for truck transport (without side covers and lid)
- Mass: 223.5 kg (492.73 lbs) for plane/boat transport (with side covers and lid)
- Crate 3 (Detector):
- Dimensions: 872 mm (34.33 in) depth × 2270 mm (89.37 in) width × 260 mm (10.24 in) height
- Mass: 104.4 kg (229.68 lbs)
### Total Mass:
- For truck transport: 641 + 210.5 + 104.4 = 955.9 kg (2104.95 lbs)
- For plane/boat transport: 641 + 223.5 + 104.4 = 968.9 kg (2133.61 lbs)
These values include the gantry, generator cabinet, control station, detector, and all related components.
This answer is automatically generated