GE Healthcare
Revision 1
Job Card ELE A013 - AWS Configuration
2. To change any of the displayed items, type the new information and confirm the entry by clicking the
Submit button.
Note:
1. This screen supports all US ASCII characters (i.e. roman alphabet letters, numbers, and classic
symbols). All accented characters are not supported, and must be substituted by appropiate let-
ters.
2. The entry Station Name is the name (hostname) that is used for the system when interacting
with the RIS server. The Station Name must be the same value as the hostname that is defined in
the TCP/IP networking configuration of
uration on page
Do not use the following characters in the Station Name:
!
ONLY USE ALPHANUMERIC CHARACTERS WITHOUT SPACES.
It is also possible to use the characters - (dash) and . (dot).
Ensure that the Station Name is no more than 12 characters long.
3. If there is more than one Senographe system on the hospital site, the names chosen must clear-
ly differentiate between them. For example, by including the unit number or name).
6-3
Set General Configuration Parameters
1. Click General under Configuration to display the General Configuration screen.
2. To change any of the displayed items, type the new information and/or select a different option in the
following:
a. The System Clock yyyy mm dd and hh:mm:ss fields set the current date and time, respec-
tively.
! Notice:
After changing the clock the system must be shut down and restarted. If this is not done, system
behavior can be unpredictable, because several interacting processes use the clock.
Chapter 7
625.
$ "
'
'
{ }
[
Service Information and Procedures Class A 2385072-16-8EN
Job Card ELE A021 - Networking Connection and Config-
]
*
@ # ? ^ _ / etc.
Page no. 574
Senographe DS
JC-ELE-A-013.fm
Need help?
Do you have a question about the Senographe DS and is the answer not in the manual?
Questions and answers
G.E.Essential l have recently bought What is the full weight.of the mamo Full weight of the console and other İtem's also measurements of each item with the main machine please All this Shipping Company required
The GE Senographe DS mammography machine is shipped in three crates with the following dimensions and weights:
- Crate 1 (Gantry, Generator Cabinet, and ramp):
- Dimensions: 2066 mm (81.34 in) depth × 848 mm (33.39 in) width × 2292 mm (90.24 in) height
- Mass: 641 kg (1410.2 lbs)
- Crate 2 (Control Station):
- Dimensions: 1110 mm (43.70 in) depth × 770 mm (30.31 in) width × 1850 mm (72.83 in) height
- Mass: 210.5 kg (464.07 lbs) for truck transport (without side covers and lid)
- Mass: 223.5 kg (492.73 lbs) for plane/boat transport (with side covers and lid)
- Crate 3 (Detector):
- Dimensions: 872 mm (34.33 in) depth × 2270 mm (89.37 in) width × 260 mm (10.24 in) height
- Mass: 104.4 kg (229.68 lbs)
### Total Mass:
- For truck transport: 641 + 210.5 + 104.4 = 955.9 kg (2104.95 lbs)
- For plane/boat transport: 641 + 223.5 + 104.4 = 968.9 kg (2133.61 lbs)
These values include the gantry, generator cabinet, control station, detector, and all related components.
This answer is automatically generated