5 Repair
5.9.2 Replacing the axis-2 gearbox
Continued
11
12
13
14
Continues on next page
500
Action
Remove the guide pins and replace with
the remaining attachment screws.
Tighten the screws.
Disconnect the brake release tool.
Perform a leak-down test.
© Copyright 2022 ABB. All rights reserved.
Note
Hex socket head cap screw: M10x30 12.9
Gleitmo 603+Geomet 500 (2 pcs)
xx2000000468
Tightening torque: 50 Nm.
See
Performing a leak-down test on
page
188.