ABB IRB 5720 Product Manual page 378

Table of Contents

Advertisement

5 Repair
5.8.4 Replacing the axis-4 motor
Continued
4
5
Refitting the axis-4 motor
1
Continues on next page
378
Action
Remove the cover, if fitted to the new spare part
motor.
Protection type Foundry Plus
Valid for axis-1, axis-2, axis-3 and axis-4.
If the motor is a new spare part, the evacuation
hole protection filter must be replaced with a
transparent plug/sight glass (enclosed with the
spare part delivery). Remove the protection filter
and install the transparent plug/sight glass.
xx1800000101
Protection filter (Stand-
ard).
Action
Fit guide pins in opposite holes.
© Copyright 2022 ABB. All rights reserved.
Note
xx2100000596
Tightening torque, transparent
plug: 20 Nm
Tightening torque, protection filter:
20 Nm
xx1600000576
xx1800000102
Transparent plug
(Foundry Plus).
Note
Guide pin, M10x150: 3HAC15521-2
Always use guide pins in pairs.
xx2100002201
Product manual - IRB 5720