11.13 o: Keypad-Related Settings
No.
Name
(Hex.)
o4-12
kWh Monitor
Initialization
(0512)
o4-13
RUN Command Counter
@ Initialize
(0528)
o4-22
Time Format
(154F)
RUN
o4-23
Date Format
(1550)
RUN
o4-24
bAT Detection Selection
(310F)
RUN
◆
o5: Log Function
No.
Name
(Hex.)
o5-01
Log Start/Stop Selection
(1551)
RUN
o5-02
Log Sampling Interval
(1552)
RUN
o5-03
Log Monitor Data 1
(1553)
RUN
o5-04
Log Monitor Data 2
(1554)
RUN
o5-05
Log Monitor Data 3
(1555)
RUN
o5-06
Log Monitor Data 4
(1556)
RUN
o5-07
Log Monitor Data 5
(1557)
RUN
o5-08
Log Monitor Data 6
(1558)
RUN
o5-09
Log Monitor Data 7
(1559)
RUN
o5-10
Log Monitor Data 8
(155A)
RUN
406
Description
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Resets the monitor values for U4-10 [kWh, Lower 4 Digits] and U4-11 [kWh, Upper 5
Digits].
0 : No Reset
1 : Reset
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Resets the monitor values for U4-02 [Num of Run Commands], U4-24 [Number of Runs
(Low)], and U4-25 [Number of Runs (High)].
0 : No Reset
1 : Reset
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time display format. This parameter is only available when using an LCD
keypad.
0 : 24 Hour Clock
1 : 12 Hour Clock
2 : 12 Hour JP Clock
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the date display format. This parameter is only available when using an LCD
keypad.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM
[Keypad Time Not Set]. This parameter is only available when you use an LCD keypad.
0 : Disable
1 : Enable (Alarm Detected)
2 : Enable (Fault Detected)
Description
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log function. This parameter is only available when using an LCD keypad.
0 : OFF
1 : ON
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log sampling cycle. This parameter is only available when using an LCD
keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Default
(Range)
0
(0, 1)
0
(0, 1)
0
(0 - 2)
0
(0 - 2)
0
(0 - 2)
Default
(Range)
0
(0 - 1)
1000 ms
(100 - 60000 ms)
101
(000, 101 - 999)
102
(000, 101 - 999)
103
(000, 101 - 999)
107
(000, 101 - 999)
108
(000, 101 - 999)
000
(000, 101 - 999)
000
(000, 101 - 999)
000
(000, 101 - 999)
YASKAWA SIEPC71061753A GA500 Technical Manual
Ref.
743
743
744
744
744
Ref.
747
747
747
747
748
748
748
748
748
749