Sign In
Upload
Manuals
Brands
YASKAWA Manuals
Controller
iQpump1000
YASKAWA iQpump1000 Manuals
Manuals and User Guides for YASKAWA iQpump1000. We have
6
YASKAWA iQpump1000 manuals available for free PDF download: User Manual, Quick Start Manual, Installation & Start?Up Manual, Setup Procedure, How To Connect And Troubleshoot
YASKAWA iQpump1000 Quick Start Manual (356 pages)
AC Drive
Brand:
YASKAWA
| Category:
DC Drives
| Size: 19 MB
Table of Contents
Simple Setup Procedure
3
Table of Contents
13
Preface & General Safety
19
Preface
20
Applicable Documentation
20
Symbols
20
Terms and Abbreviations
20
Trademarks
20
General Safety
22
Supplemental Safety Information
22
Safety Messages
23
General Application Precautions
25
Motor Application Precautions
26
Drive Label Warning Example
28
Warranty Information
28
Receiving
29
Model Number and Nameplate Check
30
Nameplate
30
Mechanical Installation
33
Mechanical Installation
34
Installation Environment
34
Installation Orientation and Spacing
34
Transporting the Drive
36
HOA Keypad Remote Usage
36
Exterior and Mounting Dimensions
39
Electrical Installation
73
Standard Connection Diagram
74
Main Circuit Connection Diagram
77
Three-Phase 200 V Class Models 2A0004 to 2A0081 Three-Phase 400 V Class Models 4A0002 to 4A0044 Three-Phase 600 V Class Models 5A0003 to 5A0032
77
Three-Phase 200 V Class Models 2A0110, 2A0138 Three-Phase 400 V Class Models 4A0058, 4A0072 Three-Phase 600 V Class Models 5A0041, 5A0052
77
Three-Phase 200 V Class Models 2A0169 to 2A0211
78
Three-Phase 400 V Class Models 4A0088 to 4A0139 Three-Phase 600 V Class Models 5A0062 to 5A0099
78
Three-Phase 200 V Class Models 2A0250 to 2A0415 Three-Phase 400 V Class Models 4A0165 to 4A0675 Three-Phase 600 V Class Models 5A0125 to 5A0242
78
Single-Phase Connections
78
Terminal Cover
79
Models 2A0004 to 2A0081, 4A0002 to 4A0044, 5A0003 to 5A0032 (IP20/NEMA Type 1 Enclosure)
79
Models 2A0110 to 2A0250, 4A0208 to 4A0675, and 5A0125 to 5A0242 (Ip00/Open Type Enclosure)
80
HOA Keypad and
81
Removing/Reattaching the HOA Keypad
81
Removing/Reattaching the
81
Top Protective Cover
84
Removing the Top Protective Cover
84
Reattaching the Top Protective Cover
84
Main Circuit Wiring
85
Factory Recommended Branch Circuit Protection
85
Main Circuit Terminal Functions
85
Protecting Main Circuit Terminals
86
Wire Gauges and Tightening Torque
87
Main Circuit Terminal and Motor Wiring
93
Control Circuit Wiring
96
Control Circuit Terminal Block Functions
96
Terminal Configuration
98
Wiring the Control Circuit Terminal
99
Control I/O Connections
101
Sinking/Sourcing Mode Switch for Digital Inputs
101
Terminals A1, A2, and A3 Input Signal Selection
102
Terminal AM/FM Signal Selection
103
Connect to a PC
104
Start-Up Programming & Operation
105
Drive Start-Up Preparation
106
Start-Up Checklist
106
Powering up the Drive
108
Setting the Real Time Clock
108
Using the HOA Keypad
111
Keys and Displays
111
LCD Display
112
ALARM (ALM) LED Displays
113
AUTO LED and HAND LED Indications
113
Menu Structure for HOA Keypad
115
Changing Parameter Settings or Values
116
Pump Application Presets
118
Parameters Set Depending on A1-03 Setting
118
Parameters Displayed Depending on A1-06 Setting
119
Iqpump Presets and Functions
120
Iqpump Presets
120
Iqpump Functions
131
Basic Iqpump Setup and Application Preset Parameters
149
Test Run with no Load
171
Load Operation Test Run
171
Test Run with Load Connected
172
Test Run with the Load Connected
172
Troubleshooting
173
Drive Alarms, Faults, Errors, and Messages
174
Types of Alarms, Faults, and Errors
174
Fault Detection
175
Fault Displays, Causes, and Possible Solutions
175
Alarm Detection
193
Alarm Codes, Causes, and Possible Solutions
193
Operator Programming Errors
203
Operator Programming Error Codes, Causes, and Possible Solutions
203
Auto-Tuning Fault Detection
207
Auto-Tuning Codes, Causes, and Possible Solutions
207
Copy Function Related Displays
211
Tasks, Errors, and Troubleshooting
211
HOA Keypad Display Messages
213
Fault Reset Methods
213
Auto-Tuning
215
Types of Auto-Tuning
215
Auto-Tuning Interruption and Fault Codes
216
Auto-Tuning Operation Example
216
Periodic Inspection & Maintenance
219
Inspection
220
Recommended Periodic Inspection
220
Periodic Maintenance
222
Replacement Parts
222
Drive Replacement
224
Replacing the Drive
224
Peripheral Devices & Options
227
Option Card Installation
228
Prior to Installing the Option
228
Communication Option Installation Example
229
Specifications
233
A.1 Power Ratings
234
Three-Phase 200 V Class Drive Models 2A0004 to 2A0030
234
Three-Phase 200 V Class Drive Models 2A0040 to 2A0211
235
Three-Phase 200 V Class Drive Models 2A0250 to 2A0415
236
Three-Phase 400 V Class Drive Models 4A0002 to 4A0031
237
Three-Phase 400 V Class Drive Models 4A0038 to 4A0165
238
Three-Phase 400 V Class Drive Models 4A0208 to 4A0675
239
Three-Phase 600 V Class Drive Models 5A0003 to 5A0032
240
Three-Phase 600 V Class Drive Models 5A0041 to 5A0099
241
Three-Phase 600 V Class Drive Models 5A0125 to 5A0242
242
A.2 Drive Specifications
243
A.3 Drive Watt Loss Data
245
A.4 Drive Derating Data
247
Single-Phase Derating
247
Temperature Derating
252
Altitude Derating
253
Parameter List
255
B.1 A: Initialization Parameters
256
A1: Initialization
256
A2: User Parameters
257
B.2 B: Application
258
B1: Operation Mode Selection
258
B2: DC Injection Braking and Short Circuit Braking
258
B3: Speed Search
259
B4: Timer Function
260
B5: PID Control
260
B6: Dwell Function
262
B8: Energy Saving
262
B.3 C: Tuning
263
C1: Acceleration and Deceleration Times
263
C2: S-Curve Characteristics
263
C3: Slip Compensation
264
C4: Torque Compensation
264
C6: Carrier Frequency
265
B.4 D: References
266
D1: Frequency Reference
266
D2: Frequency Upper/Lower Limits
267
D3: Jump Frequency
267
D4: Frequency Reference Hold and Up/Down 2 Function
268
B.5 E: Motor Parameters
269
E1: V/F Pattern
269
E2: Motor 1 Parameters
270
B.6 F: Options
272
F4: Analog Monitor Card (AO-A3)
272
F5: Digital Output Card (DO-A3)
272
F6, F7: Communication Option Card
273
B.7 H Parameters: Multi-Function Terminals
276
H1: Multi-Function Digital Inputs
276
H2: Multi-Function Digital Outputs
280
H3: Multi-Function Analog Inputs
284
H4: Analog Outputs
286
H5: Memobus/Modbus Serial Communication
287
H6: Pulse Train Input
288
B.8 L: Protection Function
289
L1: Motor Protection
289
L2: Momentary Power Loss Ride-Thru
289
L3: Stall Prevention
290
L4: Speed Detection
292
L5: Fault Restart
292
L6: Torque Detection
293
L7: Torque Limit
294
L8: Drive Protection
294
B.9 N: Special Adjustment
296
N1: Hunting Prevention
296
N2: Speed Feedback Detection Control (AFR) Tuning
296
N3: High Slip Braking (HSB) and Overexcitation Braking
296
N6: Online Tuning
297
B.10 O: Operator-Related Settings
298
O1: HOA Keypad Display Selection
298
O2: HOA Keypad Keypad Functions
299
O3: Copy Function
300
O4: Maintenance Monitor Settings
300
B.11 P: Pump Parameters
301
P1: Pump Basic
301
P2: Pump Protection
303
P3: Contactor Multiplexing
304
P4: Pump Advanced
307
P5: Pump HAND Mode
308
P6: Flow Meter Setup
309
P7: Anti-Jam
311
P9: Network Options
311
Q: PID Controller Parameters
316
Q1: Preset Setpoint
316
Q2: Geothermal Mode Setup
316
Q3: Output Current Limit
317
Q4: Water Level Control
317
Q5: Suction Pressure Control
318
B.13 S: Special Application
320
S1: Dynamic Noise Control Function
320
S2: Programmable Run Timers
320
S3: Secondary PI (PI2) Control
322
S6: Protection
324
B.14 T: Motor Tuning
325
T1: Induction Motor Auto-Tuning
325
B.15 U: Monitors
326
U1: Operation Status Monitors
326
U2: Fault Trace
328
U3: Fault History
329
U4: Maintenance Monitors
331
U5: PID Monitors
333
U6: Operation Status Monitors
334
U7: CASE Monitors
334
U9: Operation Status Monitors
334
Standards Compliance
335
European Standards
336
CE Low Voltage Directive Compliance
336
EMC Guidelines Compliance
338
C.2 UL and CSA Standards
343
UL Standards Compliance
343
CSA Standards Compliance
349
Drive Motor Overload Protection
349
Precautionary Notes on External Heatsink (Ip00/Open Type Enclosure)
351
Advertisement
YASKAWA iQpump1000 User Manual (508 pages)
AC Drive Intelligent Pump Controller
Brand:
YASKAWA
| Category:
Controller
| Size: 23 MB
Table of Contents
Electrical Installation
91
Table of Contents
91
Standard Connection Diagram
92
Main Circuit Connection Diagram
95
Terminal Block Configuration
99
Terminal Cover
101
Hoa Keypad and
103
Top Protective Cover
106
Main Circuit Wiring
107
Control Circuit Wiring
120
Control I/O Connections
125
Connect to a Pc
130
Start-Up Programming & Operation
131
Drive Start-Up Preparation
132
Powering up the Drive
134
Application Selection
138
Using the Hoa Keypad
139
Pump Application Presets
146
Iqpump Presets and Functions
150
Basic Iqpump Setup and Application Preset Parameters
210
Test Run with no Load
246
Test Run with Load Connected
247
Troubleshooting
249
Drive Alarms, Faults, Errors, and Messages
250
Fault Detection
251
Alarm Detection
270
Operator Programming Errors
285
Auto-Tuning Fault Detection
290
Copy Function Related Displays
293
Hoa Keypad Display Messages
295
Auto-Tuning
297
Appendix: a
315
Power Ratings
316
Drive Specifications
325
Drive Watt Loss Data
327
Drive Derating Data
329
YASKAWA iQpump1000 Installation & Start?Up Manual (114 pages)
Intelligent Pump Controller
Brand:
YASKAWA
| Category:
Controller
| Size: 5 MB
Table of Contents
Table of Contents
3
Preface
4
I.1 PREFACE
4
I.2 RECEIVING
11
Receiving
11
I.3 MECHANICAL INSTALLATION
14
Mechanical Installation
14
Electrical Installation
19
I.4 ELECTRICAL INSTALLATION
19
Start-Up Programming and Operation
44
I.6 TROUBLESHOOTING
74
Troubleshooting
74
I.7 DRIVE SPECIFICATIONS
85
Drive Specifications
85
I.8 PARAMETER TABLE
87
Parameter Table
87
I.9 STANDARDS COMPLIANCE
98
Standards Compliance
98
Advertisement
YASKAWA iQpump1000 Quick Start Manual (12 pages)
Brand:
YASKAWA
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Real-Time Clock Setup
3
Application Setup
6
Select Application
6
Step 9 Auto Mode Operation
11
YASKAWA iQpump1000 Setup Procedure (10 pages)
with Seametrics AG2000 Flow Meter
Brand:
YASKAWA
| Category:
Water Pump
| Size: 1 MB
Table of Contents
System Components
2
Step 1 - Make Electrical Connections
4
Step 3 - Parameter Settings
8
Troubleshooting
10
YASKAWA iQpump1000 How To Connect And Troubleshoot (5 pages)
Transducer Feedback
Brand:
YASKAWA
| Category:
DC Drives
| Size: 0 MB
Advertisement
Related Products
YASKAWA iQpump Micro CIMR-PW Series
YASKAWA iQpump
YASKAWA yasnac i80m
YASKAWA iC9200 Series
YASKAWA iC9226M
YASKAWA iC9226M-EC
YASKAWA iQpump Micro
YASKAWA iQpump Series
YASKAWA VIPA IM 053ML
YASKAWA SLIO IM 061
YASKAWA Categories
Controller
DC Drives
Servo Drives
Robotics
Control Unit
More YASKAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL