O2: Keypad Operation - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

11.13 o: Keypad-Related Settings

o2: Keypad Operation

No.
Name
(Hex.)
o2-01
LO/RE Key Function
Selection
(0505)
o2-02
STOP Key Function
Selection
(0506)
o2-03
User Parameter Default
Value
(0507)
o2-04
Drive Model (KVA)
Selection
(0508)
o2-05
Home Mode Freq Ref
Entry Mode
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-07
Keypad RUN Direction
@ Power-up
(0527)
o2-09
Reserved
(050D)
o2-19
Parameter Write during
Uv
(061F)
Expert
o2-23
External 24V Powerloss
Detection
(11F8)
RUN
o2-26
Alarm display at ext.
24V power
(1563)
o2-27
bCE Detection Selection
(1565)
404
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that lets you use
Modes.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to use
on the keypad to stop the drive when the Run
command source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to keep the settings of changed parameters as user parameter defaults
to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the Drive Model code. Set this parameter after replacing the control board.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that makes it necessary to push
frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that stops the drive if you disconnect the keypad connection cable
from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the direction of motor rotation when the drive is energized and the keypad is the
Run command source.
0 : Forward
1 : Reverse
-
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Lets you change parameters during Uv [Undervoltage].
0 : Disable
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to give a warning if the backup external 24 V power supply turns off
when the main circuit power supply is in operation.
0 : Disable
1 : Enabled
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
When you connect a backup external 24 V power supply, this parameter sets the
function to trigger an alarm when the main circuit power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : No
1 : Yes
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets drive operation if the Bluetooth device is disconnected when you operate the drive
in Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
to switch between LOCAL and REMOTE
to use the keypad to change the
YASKAWA SIEPC71061753A GA500 Technical Manual
Default
Ref.
(Range)
1
736
(0, 1)
1
737
(0, 1)
0
737
(0 - 2)
Determined by the drive
738
(-)
0
738
(0, 1)
0
738
(0, 1)
0
739
(0, 1)
-
739
0
739
( 0, 1 )
0
739
(0, 1)
0
740
(0, 1)
3
740
(0 - 4)

Advertisement

Table of Contents
loading