H Parameters: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
No.
H1 parameters to assign functions to the multi-function digital input terminals. Unused terminals should be set to "F".
Multi-Function Digital Input Terminal
H1-01
S1 Function Selection
Multi-Function Digital Input Terminal
H1-02
S2 Function Selection
Multi-Function Digital Input Terminal
H1-03
S3 Function Selection
Multi-Function Digital Input Terminal
H1-04
S4 Function Selection
Multi-Function Digital Input Terminal
H1-05
S5 Function Selection
Multi-Function Digital Input Terminal
H1-06
S6 Function Selection
Multi-Function Digital Input Terminal
H1-07
S7 Function Selection
<18> Parenthetical value is the default when parameter A1-03 = 3330 3-Wire Initialization.
<40> The availability of certain functions depends on the control method used.
H1-
Function
Setting
0
3-Wire Sequence
1
Local/Remote Selection
2
External Reference 1/2
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Name
H1: Multi-Function Digital Input
Selects the function of
terminals S1 to S7
Refer to "Multi-Function
Digital Input Selection
Table" for a description of
setting values.
H1 Multi-Function Digital Input Selections
Closed: Reverse rotation (only if the drive is set up for 3-
wire sequence)
Open: Remote, Reference 1 or 2 (b1-01/02 or b1-15/16)
Closed: Local, LED operator is run and reference source
Open: Run and frequency reference source 1 (b1-01/02)
Closed: Run and frequency reference source 2 (b1-15/16)
B.2 Parameter Table
Description
Range Def.
1 to 9F
<40>
Description
Control
Mode
Addr.
Pg.
O
V/
P
Hex
L
f
M
V
40 A A A 438
—
41 A A A 439
—
24 A A A 400
—
14 A A A 401
—
3(0)
A A A 402
—
<18>
4(3)
A A A 403
—
<18>
6(4)
A A A 404
—
<18>
Control
Mode
Pg.
V/
O
P
f
LV
M
O O O —
O O O —
O O O —
337
B