Replace Cooling Fans; Number Of Cooling Fans; Replace The Cooling Fan (Procedure A) - YASKAWA CIPR-GA50C series Technical Manual

Ac micro drives for industrial applications. 200 v class, three-phase input: 0.1 to 22 kw. 200 v class, single-phase input: 0.1 to 4.0 kw. 400 v class, three-phase input: 0.37 to 30 kw.
Table of Contents

Advertisement

8.4 Replace Cooling Fans

8.4

Replace Cooling Fans

NOTICE: Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the
fans to increase product life. If you install the fans incorrectly, it can cause damage to the drive.
To replace a cooling fan, contact Yaskawa or your nearest sales representative.

Number of Cooling Fans

Model
2001-2004
2006 - 2021
2030
2042 - 2082
Model
B001 to B006
B010, B012
B018
Model
4001 - 4004
4005 - 4012
4018, 4023
4031 - 4060

Replace the Cooling Fan (Procedure A)

DANGER! Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before servicing,
disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal capacitor
stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage decreases
below 50 Vdc. When all indicators are OFF, measure for dangerous voltages to make sure that the drive is safe. If you do work
on the drive when it is energized, it will cause serious injury or death from electrical shock. The drive has internal capacitors that
stay charged after you de-energize the drive.
CAUTION! Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait for a minimum of 15 minutes, then make
sure that the heatsink is cool before you replace the cooling fans. If you touch a hot drive heatsink, it can burn you.
NOTICE: Use the instructions in this manual to replace the cooling fans. When you do maintenance on the fans, replace all the
fans to increase product life. If you install the fans incorrectly, it can cause damage to the drive.
Remove a Fan
1.
To remove the fan finger guard from the drive, push the hooks on the left and right sides of it and pull up.
A - Fan finger guard
296
Table 8.11 Three-Phase 200 V Class
Cooling Fans
-
1
1
2
Table 8.12 Single-Phase 200 V Class
Cooling Fans
-
1
2
Table 8.13 Three-Phase 400 V Class
Cooling Fans
-
1
1
2
Figure 8.1 Remove the Fan Finger Guard
Replacement Procedure
-
A
B
A
Replacement Procedure
-
A
B
Replacement Procedure
-
A
B
A
YASKAWA SIEPC71061753A GA500 Technical Manual
Ref.
-
296
299
296
Ref.
-
296
Ref.
-
296
299
296

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga500 series

Table of Contents