Siemens G130 List Manual page 586

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
[2]: NOT logic operation 2 --> result is displayed in r2823.2.
[3]: NOT logic operation 3 --> the result is displayed in r2823.3.
r2823.0...3
CO/BO: NOT logic operation result / NOT result
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Display and BICO output for the results of the NOT logic operations.
Bit field:
Bit
00
01
02
03
Dependency:
Refer to: p2822
p2900[0...n]
CO: Fixed value 1 [%] / Fixed value 1 [%]
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-10000.00 [%]
Description:
Setting and connector output for a fixed percentage value.
Dependency:
Refer to: p2901, r2902, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling the main setpoint).
p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-10000.00 [%]
Description:
Setting and connector output for a fixed percentage value.
Dependency:
Refer to: p2900, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the supplementary setpoint)
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
- [%]
Description:
Display and connector output for frequently used percentage values.
Index:
[0] = Fixed value +0 %
[1] = Fixed value +5 %
[2] = Fixed value +10 %
[3] = Fixed value +20 %
586
Signal name
NOT logic operation 0 result
NOT logic operation 1 result
NOT logic operation 2 result
NOT logic operation 3 result
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
10000.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: PERCENT
Max
10000.00 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Access level: 3
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 3
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 1
Func. diagram: 1021
Unit selection: -
Expert list: 1
Factory setting
- [%]