2 Parameters
2.2 List of parameters
r0721
CU digital inputs terminal actual value / CU DI term act val
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
CU_G150_DP
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the
simulation mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
20
21
Notice:
Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note:
If a DI/DO is parameterized as output (p0728.x = 1), then r0721.x = 0 is displayed.
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
r0722.0...21
CO/BO: CU digital inputs status / CU DI status
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
CU_G150_DP
P-Group: Commands
Not for motor type: -
Min
-
Description:
Display and BICO output for the status of the digital inputs.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
254
Signal name
DI 0 (X122.1/X121.1)
DI 1 (X122.2/X121.2)
DI 2 (X122.3/X121.3)
DI 3 (X122.4/X121.4)
DI 4 (X132.1 / -)
DI 5 (X132.2 / -)
DI 6 (X132.3 / -)
DI 7 (X132.4 / -)
DI/DO 8 (X122.9/X121.7)
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 12 (X132.9/X131.1)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI 16 (X122.5/X120.3)
DI 17 (X122.6/X120.4)
DI 20 (X132.5/X120.9)
DI 21 (X132.6/X120.10)
Signal name
DI 0 (X122.1/X121.1)
DI 1 (X122.2/X121.2)
DI 2 (X122.3/X121.3)
DI 3 (X122.4/X121.4)
DI 4 (X132.1 / -)
DI 5 (X132.2 / -)
DI 6 (X132.3 / -)
DI 7 (X132.4 / -)
DI/DO 8 (X122.9/X121.7)
DI/DO 9 (X122.10/X121.8)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
High
High
High
High
High
High
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 2119, 2120,
2121, 2130, 2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
Access level: 1
Func. diagram: 2119, 2120,
2121, 2130, 2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Low
Low
Low
Low
Low
Low
Low
SINAMICS G130/G150