Siemens G130 List Manual page 888

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
DAP ID: Device Access Point ID
DAP ID = 20008 hex: SINAMICS CBE20 V4.6
DAP ID = 20009 hex: SINAMICS CBE20 V4.7
DAP ID = 2000A hex: SINAMICS CBE20 V4.8
DAP ID = 20209 hex: SINAMICS CBE25 V4.7
r8960[0...2]
PN subslot controller assignment / PN subslot assign
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: -
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150,
Min
TB30, ENC
0
Description:
Displays the controller assignment of a PROFINET subslot on the actual drive object.
The display is only relevant for Shared Device (p8929 = 2).
Index:
[0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency:
Refer to: r8961, r8962
Note:
Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
r8961[0...3]
PN IP Address Remote Controller 1 / IP Addr Rem Ctrl1
CU_G130_PN,
Can be changed: -
CU_G150_PN
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the IP address of the first PROFINET controller connected with the device via PN onboard.
r8962[0...3]
PN IP Address Remote Controller 2 / IP Addr Rem Ctrl2
CU_G130_PN,
Can be changed: -
CU_G150_PN
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
0
Description:
Displays the IP address of the second PROFINET controller connected with the device via PN onboard.
The display is only relevant for Shared Device (p8929 = 2) or system redundancy.
p8969
PROFIsafe wait for clock synchronization / PS wait sync
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
0
Description:
Setting for the behavior of a PROFIsafe communication connection depending on another isochronous
communication connection.
Value:
0:
1:
Recommendation:
A value of 1 is recommended, if problems are encountered with the PROFIsafe connection when synchronizing.
888
No
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents