Siemens G130 List Manual page 1000

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9785[0...1]
SI Motion diagnostics sensorless minimum current / Diag sl I_min
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [mA]
Description:
Display to diagnose currents of the encoderless actual value sensing.
Index:
[0] = Minimum current parameterized
[1] = Minimum current measured
Dependency:
Refer to: p9588
Note:
For index 0:
Displays the parameterized minimum current of p9588.
For index 1:
Displays the currently measured current of the encoderless actual value sensing
r9786[0...2]
SI Motion diagnostics sensorless angle / Diag sl angle
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [°]
Description:
Display to diagnose the angle for sensorless actual value sensing.
Index:
[0] = Plausibility angle actual value
[1] = Voltage angle actual value
[2] = Current angle actual value
Dependency:
Refer to: p9585
Note:
For index 0:
Displays the actual plausibility angle.
For index 1:
Displays the actual voltage angle.
For index 2:
Displays the actual current angle.
r9787
SI Motion diagnostics sensorless velocity deviation / Diag sl v_dev
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [mm/min]
Description:
Displays the actual velocity deviation for sensorless actual value sensing.
This value is calculated when setting p9585/p9385.
The actual velocity has a deviation of +/- r9787 for 6 ms * p9585/p9385 within a monitoring time of 1 s.
Dependency:
Refer to: p9585
Note:
For linear axes, the following unit applies: millimeters per minute
For rotary axes, the following unit applies: revolutions per minute
1000
Calculated: -
Dyn. index: -
Unit group: 6_3
Scaling: -
Max
- [mA]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [°]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [mm/min]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [mA]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [mm/min]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents