2 Parameters
2.2 List of parameters
p0294
Power unit alarm with I2t overload / PU I2t alrm thresh
B_INF
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Converter
Not for motor type: -
Min
10.0 [%]
Description:
Sets the alarm threshold for the I2t power unit overload.
Dependency:
Refer to: r0036
Refer to: A07805
Note:
The parameter is only relevant for booksize units!
p0295
Fan run-on time / Fan run-on time
VECTOR_G, B_INF
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Converter
Not for motor type: -
Min
0 [s]
Description:
Sets the fan run-on time after the pulses for the power unit have been canceled.
Note:
- Under certain circumstances, the fan can continue to run for longer than was set (e.g. as a result of the excessively
high heat sink temperature).
- For values less than 1 s, a 1 s run on time for the fan is active.
r0296
DC link voltage undervoltage threshold / Vdc U_lower_thresh
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage condition.
Dependency:
Refer to: p0278
Refer to: F30003
Note:
The value depends on the device type and the selected device rated voltage (p0210).
For booksize drive units, the following applies:
The undervoltage threshold can be reduced with p0278.
r0296
DC link voltage undervoltage threshold / Vdc U_lower_thresh
B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage condition.
Dependency:
Refer to: F30003
Note:
The value depends on the device type and the selected device rated voltage (p0210).
128
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
100.0 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
600 [s]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [V]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 8021
Unit selection: -
Expert list: 1
Factory setting
95.0 [%]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [s]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 2
Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
Unit selection: -
Expert list: 1
Factory setting
- [V]