Siemens G130 List Manual page 425

Hide thumbs Also See for G130:
Table of Contents

Advertisement

r1606
CO: Pulse technique pattern actual / Puls pattern act
VECTOR_G (n/M)
Can be changed: -
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: ASM, SESM, REL
Min
0
Description:
Displays the currently applied pulse patterns for estimating the continuous rotor position.
Value:
0:
1:
2:
Dependency:
Refer to: p1605, p1750
p1607[0...n]
Pulse technique stimulus / Puls stimulus
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, SESM, REL
Min
0.000 [mVs]
Description:
Sets the excitation amplitude (voltage-time pulse) for the pulse technique for estimating the continuous rotor position.
Dependency:
Refer to: p1605, p1750
r1608[0...8]
CO: Pulse technique response / Puls response
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: ASM, SESM, REL
Min
- [A]
Description:
Displays the signal responses to the excitation of the pulse technique.
Index:
[0] = Phase R
[1] = Phase S
[2] = D estimated
[3] = Q estimated
[4] = D estimated AC
[5] = Q estimated AC
[6] = Pointer length AC
[7] = D estimated AC smooth
[8] = Q estimated AC smooth
Dependency:
Refer to: p1605, p1607, p1750
Note:
For index 7, 8:
Displays the smoothed values (smoothing time p0045) from indices 4 and 5.
p1609[0...n]
I/f operation current setpoint / I/f op I_setp
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PMSM, REL
Min
0.00 [Arms]
Description:
Sets the stator current setpoint for operation of a separately excited synchronous motor (SESM) in operating mode I/f
(p1300 = 18).
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
None
pm
ppmm
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
20000.000 [mVs]
Calculated: -
Dyn. index: -
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: CALC_MOD_ALL
Dyn. index: DDS, p0180
Unit group: 6_2
Scaling: -
Max
10000.00 [Arms]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
32.000 [mVs]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Arms]
425