2 Parameters
2.2 List of parameters
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
-
Description:
Sets the mode-dependent properties for energy-saving.
Index:
[0] = Reserved
[1] = Mode 2
Bit field:
Bit
00
Note:
Pe: PROFIenergy profiles
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned8
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
-
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
Bit field:
Bit
00
01
Note:
Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
p5614
BI: Pe set switching-on inhibited signal source / Pe sw-on_inh s_src
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32 / Binary
CU_G130_DP,
P-Group: -
CU_G150_DP
Not for motor type: -
Min
-
Description:
Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency:
Refer to: r5613
Note:
Pe: PROFIenergy profiles
p6397
Motor Module phase shift second system / MM ph_sh 2nd sys
VECTOR_G
Can be changed: T
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the phase shift of the second system with respect to the first system for the Motor Module for a 12-pulse gating
unit.
Value:
0:
1:
2:
3:
744
Signal name
Reserved
Signal name
Pe active
Pe inactive
Shift by +30 °
Shift by -30 °
Shift by 0 °
Shift by +90 °
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 0110 bin
[1] 0000 bin
0 signal
No
Access level: 3
Func. diagram: 2382
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Access level: 3
Func. diagram: 2382
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0