2 Parameters
2.2 List of parameters
r7100[0...99]
Par_circuit ring buffer fault/alarm code / Fault/alarm code
VECTOR_G (Parallel),
Can be changed: -
B_INF (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the fault/alarm code.
Dependency:
Refer to: r7101, r7102, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7101[0...99]
Par_circuit ring buffer data set number / Ring buffer Ds_no
VECTOR_G (Parallel),
Can be changed: -
B_INF (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
p7101 < 100:
Displays the Power unit Data Set number (PDS).
p7101 >= 100:
Displays the Voltage Sensing Module Data Set number (VSMDS)
Dependency:
Refer to: r7100, r7102, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7102[0...99]
Par_circuit ring buffer fault/alarm received / F/A received
VECTOR_G (Parallel),
Can be changed: -
B_INF (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the relative system runtime when the fault or alarm occurred.
Dependency:
Refer to: r7100, r7101, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
758
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents