2 Parameters
2.2 List of parameters
r4705[0...1]
Trace status / Trace status
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Displays the actual status of the trace.
Value:
0:
1:
2:
3:
4:
5:
6:
Index:
[0] = Trace 0
[1] = Trace 1
r4706
Measuring function status / Meas fct status
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Displays the actual status of the measuring function.
Value:
0:
1:
2:
3:
4:
5:
p4707
Measurement function configuration / Meas fct config
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
0
Description:
Setting to configure the measurement function.
Value:
0:
1:
Dependency:
The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
Note:
This parameter involves the free measuring functions and is only active for p4810=6.
For value = 0:
The free measuring function is parameterized with master control.
For value = 1:
The free measuring function is parameterized without master control.
702
Trace inactive
Trace is recording presamples
Trace is waiting for trigger event
Trace is recording
Recording (trace) ended
Trace inactive with permissible configuration data
Trace inactive with inadmissible configuration data
Measurement function inactive
Measuring function parameterization checked
Measuring function waits for stabilizing time
Measuring function recording (tracing)
Measuring function trace ended with error
Measuring function trace successfully completed
Standard
Free meas fct
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
5
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0