2 Parameters
2.2 List of parameters
p4096
TB30 digital inputs simulation mode setpoint / TB30 DI sim setpt
TB30
Can be changed: U, T
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the setpoint for the input signals in the simulation mode of the digital inputs of the Terminal Board 30 (TB30).
Bit field:
Bit
00
01
02
03
Dependency:
The simulation of a digital input is selected using p4095.
Refer to: p4095
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
p4097[0...1]
TM31 analog inputs simulation mode / TM31 AI sim_mode
TM31
Can be changed: U, T
Data type: Integer16
P-Group: Terminals
Not for motor type: -
Min
0
Description:
Sets the simulation mode for the analog inputs of Terminal Module 31 (TM31).
Value:
0:
1:
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
p4097[0...1]
TB30 analog inputs simulation mode / TB30 AI sim_mode
TB30
Can be changed: U, T
Data type: Integer16
P-Group: Terminals
Not for motor type: -
Min
0
Description:
Sets the simulation mode for the analog inputs of the Terminal Board 30 (TB30).
Value:
0:
1:
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Dependency:
The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
664
Signal name
DI 0 (X481.1)
DI 1 (X481.2)
DI 2 (X481.3)
DI 3 (X481.4)
Terminal evaluation for analog input x
Simulation for analog input x
Terminal evaluation for analog input x
Simulation for analog input x
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
High
High
High
High
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 2
Func. diagram: 9099, 9100
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Low
Low
Low
Low
Access level: 2
Func. diagram: 9566, 9568
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 9104
Unit selection: -
Expert list: 1
Factory setting
0