p10204
SI Motion SBT motor type / SBT motor type
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Selects the motor type for the safe brake test.
Value:
0:
1:
Dependency:
Refer to: F01787
Note:
For safe functions that are not enabled (p9501 = 0), the following applies:
- p10204 is automatically set the same as r0108.12 when the system boots.
When the safe brake test is enabled (10201.0 = 1), the following applies:
- p10204 is checked when the system boots to see that it matches r0108.12.
p10208[0...1]
SI Motion SBT test torque ramp time / SBT M_test t_ramp
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
20 [ms]
Description:
Sets the time, during which the test torque is ramped up against the closed brake.
The test torque is then ramped down after the safe brake test.
Index:
[0] = Brake 1
[1] = Brake 2
Note:
The set time is rounded internally to an integer multiple of the monitoring clock cycle.
p10209[0...1]
SI Motion SBT brake holding torque / SBT brake M_stop
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
1.00 [Nm]
Description:
Sets the effective holding torque on the motor side of the brake to be tested.
Index:
[0] = Brake 1
[1] = Brake 2
Dependency:
The holding torque of an external brake should be converted to the motor side.
Conversion factor:
- motor type = rotary and axis type = linear: p9522 / (p9521 x p9520)
- otherwise: p9522 / p9521
Further, the efficiency of the mechanical system should be taken into account.
Refer to: p10210, p10220
Note:
The test torque effective for the brake test can be set for each sequence using a factor (p10210, p10220).
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Rotating
Linear
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
60000.00 [Nm]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
1000 [ms]
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
10.00 [Nm]
1061