[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Dependency:
Refer to: p2061
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
IF1: Interface 1
r2053[0...24]
IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the PZD (actual values) with word format sent to the fieldbus controller.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Note:
IF1: Interface 1
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-