2 Parameters
2.2 List of parameters
4:
5:
6:
7:
8:
9:
Index:
[0] = Trace channel 0
[1] = Trace channel 1
[2] = Trace channel 2
[3] = Trace channel 3
[4] = Trace channel 4
[5] = Trace channel 5
[6] = Trace channel 6
[7] = Trace channel 7
[8] = Trace channel 8
[9] = Trace channel 9
[10] = Trace channel 10
[11] = Trace channel 11
[12] = Trace channel 12
[13] = Trace channel 13
[14] = Trace channel 14
[15] = Trace channel 15
Dependency:
Refer to: p7791, p7792
Refer to: A01302
Note:
In the operation state, when a trigger event occurs, the trace data of the signals are saved in the component. The
oldest trace data are overwritten after more than 5 trigger events.
The trigger event can be set in p7791.
By activating p7792, the trace data of the component is written to files on the non-volatile storage medium (memory
card). Experts can then evaluate this data.
p7791
Component trace trigger / Comp trace trigger
VECTOR_G, B_INF
Can be changed: U, T
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the trigger event for the component trace.
Value:
0:
1:
2:
Dependency:
Refer to: p7790, p7792
Note:
F30001 is output if the power unit detects an overcurrent condition.
F30002 is output if the power unit detects an overvoltage condition in the DC link.
F30021 is output if the power unit detects a ground fault.
F30022 is output if the power unit detects an Uce fault.
p7792
Upload component trace data / Upload comp trace
VECTOR_G, B_INF
Can be changed: U, T
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Setting to upload and save the trace data of the component trace.
Experts can then evaluate this data.
For p7792 = 1, the trace data of the component is written to files on the memory card in a non-volatile fashion.
The parameter is then automatically set to zero.
778
Phase current W
IGBT chip temperature
Heat sink temperature
DC link voltage
Modulat_depth
Angle
Overcurrent, overvoltage, ground fault, Uce
Time-critical message
Uce
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0