2 Parameters
2.2 List of parameters
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For bit 02:
When the function is activated, track monitoring can be deactivated by setting p0437.26.
For bit 05:
When the function is activated, a frequency setpoint and a direction for traveling can be entered via an encoder
interface.
p0407[0...n]
Linear encoder grid division / Enc grid div
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0 [nm]
Description:
Sets the grid division for a linear encoder.
In conjunction with the values in p0418/p0419, the grid division defines the transfer format for position actual values
Gn_XIST1 (r0482) and Gn_XIST2 (r0483).
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The lowest permissible value is 250 nm.
This value does not always correspond to the grid division of the measuring device. For a DRIVE-CLiQ encoder, a
value is entered here that facilitates optimum transfer of the resolution (p0422).
p0408[0...n]
Rotary encoder pulse number / Rot enc pulse No.
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of pulses for a rotary encoder.
In conjunction with the values in p0418/p0419, the pulse number defines the transfer format for position actual values
Gn_XIST1 (r0482) and Gn_XIST2 (r0483).
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The smallest permissible value is 1 pulse.
The number of pole pairs for a resolver is entered here.
This value does not always correspond to the pulse number of the measuring device. For a DRIVE-CLiQ encoder, a
value is entered here that facilitates optimum transfer of the resolution (p0423).
166
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
250000000 [nm]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
16777215
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 4010, 4704
Unit selection: -
Expert list: 1
Factory setting
16000 [nm]
Access level: 3
Func. diagram: 4010, 4704
Unit selection: -
Expert list: 1
Factory setting
2048