r0790[0...2]
Test sockets physical address signal value / TestSktsPhyAddrVal
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Terminals
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the actual value of a signal determined via a physical address.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Only effective when p0776 = 97 or p0776 = 96.
Refer to: p0788
p0795
CU digital inputs simulation mode / CU DI simulation
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
CU_G150_DP
P-Group: Commands
Not for motor type: -
Min
-
Description:
Sets the simulation mode for digital inputs.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
20
21
Dependency:
The setpoint for the input signals is specified using p0796.
Refer to: p0796, p9620
Notice:
If a digital input is used as signal source for the function "STO" (BI: p9620) then it is not permissible to select the
simulation mode and this is rejected.
Regarding the terminal designation:
The first designation stands for CU320, the second for CU310.
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
264
Signal name
DI 0 (X122.1/X121.1)
DI 1 (X122.2/X121.2)
DI 2 (X122.3/X121.3)
DI 3 (X122.4/X121.4)
DI 4 (X132.1 / -)
DI 5 (X132.2 / -)
DI 6 (X132.3 / -)
DI 7 (X132.4 / -)
DI/DO 8 (X122.9/X121.7)
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 12 (X132.9/X131.1)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI 16 (X122.5/X120.3)
DI 17 (X122.6/X120.4)
DI 20 (X132.5/X120.9)
DI 21 (X132.6/X120.10)
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
List Manual (LH2), 07/2016, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 2020, 2030,
2031, 2100, 2119, 2120, 2130,
2131, 2132, 2133
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 0000
0000 0000 0000 bin
0 signal
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
Terminal eval
SINAMICS G130/G150
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents