r7229[0...n]
CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Display and connector output for the measured sum of the currents in phases U, V and W as instantaneous value.
The summed value of all power units is displayed in r0069[6].
r7230[0...n]
CO: Par_circuit DC link voltage actual value / Vdc_act
VECTOR_G (Parallel),
Can be changed: -
B_INF (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the measured actual value of the DC link voltage.
The average value of all power units is displayed in r0070.
r7231[0...n]
CO: Par_circuit phase voltage actual value phase U / U_phase U act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the actual voltage, phase U.
The average value of all power units is displayed in r0089[0].
r7232[0...n]
CO: Par_circuit phase voltage actual value phase V / U_phase V act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the actual voltage, phase V.
The average value of all power units is displayed in r0089[1].
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / U_phase W act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: PDS, p0120
Unit group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 5_2
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 5_3
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 5_3
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: PDS, p0120
Unit group: 5_3
Scaling: p2001
Max
- [V]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
765