p10011[0...5]
SI TM54F drive group assignment / SI drv_gr assign
TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
1
Description:
Sets the drive group for the drives that are available.
A drive group is a combination of several drives with the same types of behavior.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Note:
If the basic functions are controlled via the TM54F, then within a drive group, only drives with basic functions or
drives with extended functions can be assigned.
p10012[0...5]
SI TM54F Motor/Hydraulic Module Node Identifier Word 1 / SI MM/HM Node ID 1
TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the actual Node Identifier (word 1, bit 0 ... 31) for the Motor/Hydraulic Modules.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Dependency:
Refer to: p10013, p10014
Note:
The Node Identifier (96 bit) is represented in the following 3 parameters.
p10012[0] word 1 (bit 0 ... 31) for Motor/Hydraulic Module 1
...
p10012[5] word 1 (bit 0 ... 31) for Motor/Hydraulic Module 6
p10013[0] word 2 (bit 32 ... 63) for Motor/Hydraulic Module 1
...
p10013[5] word 2 (bit 32 ... 63) for Motor/Hydraulic Module 6
p10014[0] word 3 (bit 64 ... 95) for Motor/Hydraulic Module 1
...
p10014[5] word 3 (bit 64 ... 95) for Motor/Hydraulic Module 6
p10013[0...5]
SI TM54F Motor/Hydraulic Module Node Identifier Word 2 / SI MM Node ID 2
TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the actual Node Identifier (word 2, bit 32 ... 63) for the Motor/Hydraulic Modules.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
1038
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 2892
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex