r1538
CO: Upper effective torque limit / M_max upper eff
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Display and connector output for the actual effective upper torque limit.
Note:
The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
This torque limit can be influenced by p0543.
The following applies for VECTOR:
- this is possibly the case for a rotating measurement (see p1960).
- additional variable torque limiting is possible (e.g. binector input p1540).
r1539
CO: Lower effective torque limit / M_max lower eff
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Display and connector output for the actual effective lower torque limit.
Note:
The effective lower torque limit is reduced with respect to the selected lower torque limit p1521, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
The following applies in the case of VECTOR: This may be the case for rotating measurements (see p1960).
The following applies in the case of VECTOR: Further variable torque limiting is possible (e.g. binector input p1541).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
This torque limit can be influenced by p0543.
p1540[0...n]
CI: Torque limit speed controller upper scaling / M_max n-ctr upScal
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the upper torque limiting to limit the speed controller output.
p1541[0...n]
CI: Torque limit. speed controller lower scaling / M_max nctr lowScal
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 6020, 6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 2
Func. diagram: 6020, 6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 6020, 6060
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 6020, 6060
Unit selection: -
Expert list: 1
Factory setting
1
411

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents