2 Parameters
2.2 List of parameters
r10240
SI Motion SBT test torque diagnostics / SBT M_test diag
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [Nm]
Description:
Displays the effective maximum test torque on the motor side for a safe brake test.
Dependency:
The test torque for an external brake should be converted to the load side.
Conversion factor:
- motor type = rotary and axis type = linear: (p9521 x p9520) / p9522
- otherwise: p9521 / p9522
Further, the efficiency of the mechanical system should be taken into account.
Refer to: p10210, p10220
Note:
The value remains displayed until the start of the next test sequence.
r10241
SI Motion SBT load torque diagnostics / SBT M_load diag
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [Nm]
Description:
Displays the load torque for a safe brake test.
When initializing the brake test, this load torque is available at the drive.
Note:
The value remains displayed until the brake test is deselected.
r10242
SI Motion SBT state diagnostics / SBT state diag
VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Displays the actual state of the safe brake test.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16:
1066
Brake test inactive, wait for SBT selection
Setpoint input drive
Determining the load
Brake test is initialized, wait for start of test sequence
Start test seq
Closing the brake, establishing the test torque
Brake test active, wait for test duration sequence
Reduce test torque
Wait for the brake to open
Brake test successfully completed, wait for start deselection
Change to brake test initialized - fault acknowledgment
Brake test canceled, torque is reduced
Brake test canceled, wait for brake to open
Brake test ended with error, wait for acknowledgment
Brake opening timer elapsed
Error when initializing the brake test, wait for acknowledgment
Change to brake test inactive, acknowledgment active
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
- [Nm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150