CO: Actual speed smoothed signals / n_act smth message
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
- [rpm]
Description:
Display and connector output of the smoothed speed actual value for messages.
Dependency:
Refer to: p2153
p2174[0...n]
Torque threshold value 1 / M_thresh val 1
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the torque threshold value for the messages:
"Torque setpoint < torque threshold value 1 and n_set reached" (BO: r2198.9)
"Torque setpoint < torque threshold value 1" (BO: r2198.10)
"Torque setpoint > torque threshold value 1" (BO: r2198.13)
Dependency:
Refer to: p2195, r2198
p2175[0...n]
Motor blocked speed threshold / Mot lock n_thresh
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold for the message "Motor blocked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2177, r2198
Refer to: F07900
Note:
The following applies for encoderless vector control for induction motors:
At low speeds in open-loop speed controlled operation (see p1755, p1756), a blocked motor cannot be detected.
The following applies for encoderless vector control for permanent magnet synchronous motors:
At low speeds in open-loop speed controlled operation (see p1755, p1756), a blocked motor can only be detected if
p2175 = p1755, and p1750.6 is set to 1.
p2177[0...n]
Motor blocked delay time / Mot lock t_del
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.000 [s]
Description:
Sets the delay time for the message "Motor blocked" (BO: r2198.6).
Dependency:
Refer to: p0500, p2175, r2198
Refer to: F07900
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: DDS, p0180
Unit group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
65.000 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 2
Func. diagram: 8012
Unit selection: p0505
Expert list: 1
Factory setting
5.13 [Nm]
Access level: 3
Func. diagram: 8012
Unit selection: p0505
Expert list: 1
Factory setting
120.00 [rpm]
Access level: 2
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
1.000 [s]