2 Parameters
2.2 List of parameters
p9495
BICO behavior for deactivated drive objects / Behav for deact DO
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150,
Min
TB30, ENC
0
Description:
Sets the behavior for BICO interconnections to drive objects that are either not capable of operation or have been
deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Value:
0:
1:
2:
Dependency:
Refer to: p9496, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
For p9495 = 0, the following applies:
- the number of interconnections is zero (p9497 = 0).
For p9495 not equal to 0, the following applies:
- the BI/CI parameters involved are listed in p9498[0...29] (signal sink).
- the associated BO/CO parameters are listed in p9499[0...29] (signal source).
p9496
BICO behavior when activating drive objects / Behav when act DO
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: -
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150,
Min
TB30, ENC
0
Description:
Sets the behavior when activating BICO interconnections to drive objects that are either not capable of operation or
have been deactivated.
Value:
0:
1:
2:
Dependency:
Refer to: p9495, p9497, p9498, p9499
Refer to: A01318, A01507
Note:
The BI/CI parameters involved are listed in p9498[0...29] (signal sink).
The associated BO/CO parameters are listed in p9499[0...29] (signal source).
After p9496 = 1, 2 the following applies:
- p9497 = 0
- p9496 = 0
p9497
BICO interconnections to deactivated drive objects number / Interconn obj qty
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned16
CU_G130_DP,
P-Group: Commands
CU_G150_DP,
Not for motor type: -
VECTOR_G, B_INF,
TM31, TM120, TM150,
Min
TB30, ENC
0
Description:
Displays the number of saved BICO interconnections to drive objects that are either not capable of operation or have
been deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
926
Inactive
Save interconnections
Save interconnections and establish the factory setting
Inactive
Restore the interconnections from the list
Delete the interconnections from the list
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0