p5602[0...1]
Pe energy-saving mode pause time minimal / Pe mod t_pause min
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
300000 [ms]
Description:
Sets the minimum possible pause time for the energy-saving mode.
The value is the sum of the following times:
- Energy-saving mode transition time
- Operating state transition time regular
- Energy-saving mode, time of minimum stay
Index:
[0] = Reserved
[1] = Mode 2
Note:
It is not permissible that the value is less than the sum of the "energy-saving mode transition time" and the "operating
state transition time" (system properties).
Pe: PROFIenergy profiles
p5606[0...1]
Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
0 [ms]
Description:
Sets the time of maximum stay for the energy-saving mode.
Index:
[0] = Reserved
[1] = Mode 2
Note:
Pe: PROFIenergy profiles
p5611
Pe energy-saving properties general / Pe properties gen
CU_G130_PN,
Can be changed: T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Communications
CU_G150_DP
Not for motor type: -
Min
-
Description:
Sets the general properties for energy-saving.
Bit field:
Bit
00
01
02
Note:
Pe: PROFIenergy profiles
PROFIdrive state S3: ready
PROFIdrive state S4: operation
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
Inhibit PROFIenergy control commands
Drive initiates OFF1 when transitioning to
energy-saving mode
Trans to energy-saving mode from
PROFIdrive state S3/S4 poss
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
4294967295 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2381
Unit selection: -
Expert list: 1
Factory setting
[0] 300000 [ms]
[1] 480000 [ms]
Access level: 3
Func. diagram: 2381
Unit selection: -
Expert list: 1
Factory setting
4294967295 [ms]
Access level: 3
Func. diagram: 2381, 2382
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
No
No
No
FP
-
-
-
743