Siemens G130 List Manual page 1035

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p10002
SI TM54F F-DI changeover discrepancy time / SI F-DI chg t
TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
1.00 [ms]
Description:
Sets the discrepancy time for digital inputs.
The signal states at the two associated digital inputs (F-DI) must assume the same state within this discrepancy time.
Note:
The discrepancy time of the F-DIs must always be set higher than the highest value of parameter p9780 or p9500 of
the drives that use safety with TM54F. The set time is rounded internally to an integer multiple of the TM54F
sampling time (r10015).
p10003
SI TM54F forced checking procedure timer / SI dyn t
TM54F_MA
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [h]
Description:
Sets the time to carry out the forced checking procedure (test stop).
Within the parameterized time, the digital inputs/outputs must must have been subject to a forced checking
procedure at least once. The forced checking procedure is started with binector input p10007 = 0/1 signal.
Dependency:
Refer to: p10001, p10007, p10046
r10004[0...1]
SI TM54F parameter actual checksum / SI par CRC act
TM54F_MA,
Can be changed: -
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the actual checksum of the checksum-checked parameters for the Terminal Module 54F (TM54F).
Index:
[0] = Checksum HW-independent TM54F parameters
[1] = Checksum HW-dependent TM54F parameters (MM)
p10005[0...1]
SI TM54F parameter reference checksum / SI par CRC target
TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Displays the reference checksum of the checksum-checked parameters for the Terminal Module 54F (TM54F).
Index:
[0] = Checksum HW-independent TM54F parameters
[1] = Checksum HW-dependent TM54F parameters (MM)
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
2000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8760.00 [h]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2893, 2894
Unit selection: -
Expert list: 1
Factory setting
500.00 [ms]
Access level: 3
Func. diagram: 2892
Unit selection: -
Expert list: 1
Factory setting
8.00 [h]
Access level: 3
Func. diagram: 2891
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2891
Unit selection: -
Expert list: 1
Factory setting
0000 hex
1035

Hide quick links:

Advertisement

Table of Contents