Note:
SLS: Safely Limited Speed / SG: Safely reduced speed
p9531[0...3]
SI Motion SLS (SG) limit values (Control Unit) / SI Mtn SLS lim CU
VECTOR_G (Safety
Can be changed: C2(95)
rot)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the limit values for the function "Safely Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
Refer to: p9532, p9561, p9563
Refer to: C01714
Note:
SLS: Safely Limited Speed / SG: Safely reduced speed
p9532[0...15]
SI Motion SLS (SG) override factor (Control Unit) / SI Mtn SLS over CU
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.000 [%]
Description:
Sets the override factor for the limit value for SLS2 and SLS4 for the function "Safely Limited Speed" (SLS).
Index:
[0] = SLS (SG) override factor 0
[1] = SLS (SG) override factor 1
[2] = SLS (SG) override factor 2
[3] = SLS (SG) override factor 3
[4] = SLS (SG) override factor 4
[5] = SLS (SG) override factor 5
[6] = SLS (SG) override factor 6
[7] = SLS (SG) override factor 7
[8] = SLS (SG) override factor 8
[9] = SLS (SG) override factor 9
[10] = SLS (SG) override factor 10
[11] = SLS (SG) override factor 11
[12] = SLS (SG) override factor 12
[13] = SLS (SG) override factor 13
[14] = SLS (SG) override factor 14
[15] = SLS (SG) override factor 15
Dependency:
Refer to: p9501, p9531
Note:
The actual override factor for SLS2 and SLS4 is selected using the safety-relevant inputs (SGE).
SLS: Safely Limited Speed / SG: Safely reduced speed
p9533
SI Motion SLS setpoint velocity limiting (Control Unit) / SI Mtn SLS set_lim
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.000 [%]
Description:
This is an evaluation factor to define the setpoint limit from the selected actual speed limit.
The active SLS limit value is evaluated with this factor and is made available as setpoint limit in r9733.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
1000000.00 [rpm]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
100.000 [%]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
100.000 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2000.00 [rpm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
80.000 [%]
939