Siemens G130 List Manual page 937

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Note:
- after starting the copy function (p9700 = 57 hex), p9523 is set the same as r0470.
p9524
SI Motion Redundant coarse pos. value fine resolution bits (CU) / SI Mtn fine bit CU
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
-16
Description:
Sets the number of valid bits for the fine resolution of the redundant coarse position value.
The encoder that is used for the safe motion monitoring functions on the Control Unit must be parameterized in this
parameter.
Dependency:
Refer to: r0471, p9324
Note:
- after starting the copy function (p9700 = 57 hex), p9524 is set the same as r0471.
p9525
SI Motion Redundant coarse pos. value relevant bits (CU) / Relevant bits CU
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the number of relevant bits for the redundant coarse position value.
The encoder that is used for the safe motion monitoring functions on the Control Unit must be parameterized in this
parameter.
Dependency:
Refer to: p0414, r0472, p9325
Note:
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9525 is automatically set the same as r0472 when the system boots.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9525 is checked to see that it matches r0472.
p9526
SI Motion encoder assignment second channel / SI Mtn enc chan 2
VECTOR_G
Can be changed: C2(95)
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
1
Description:
Sets the number of the encoder that the second channel (control, Motor Module) uses for safe motion monitoring
functions.
Dependency:
For the safe motion monitoring functions, the redundant safety position actual value sensing must be activated in the
appropriate encoder data set (p0430.19 = 1).
Refer to: p0187, p0188, p0189, p0430
Note:
For p9526 = 1, the encoder for the closed-loop speed control is used for the second channel of the motion monitoring
functions (1-encoder system).
A change only becomes effective after a POWER ON.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
3
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
16
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
937

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents