Note:
For bit 00 ... 09:
Used to control internal sequences during the flying restart.
Depending on the motor type (p0300), the number of active bits differs.
For bits 10 ... 17:
Are used to monitor the flying restart sequence.
p1206[0...9]
Automatic restart faults not active / AR fault not act
VECTOR_G, B_INF
Can be changed: U, T
Data type: Unsigned16
P-Group: Functions
Not for motor type: -
Min
0
Description:
Sets faults for which automatic restart should not be effective.
Dependency:
The setting is only effective for p1210 = 6, 16.
Refer to: p1210
p1207
BI: AR connection following drive object / AR connection DO
B_INF
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Functions
Not for motor type: -
Min
-
Description:
Modifies the precharging monitoring of the infeed.
The active automatic restart (AR) of the following drive object can be interconnected using this binector input (BI:
p1207 = r1214.2).
This means that when the automatic restart is operational, the precharging monitoring of the infeed is deactivated
and is only re-activated under the following conditions:
- the absolute current in the DC link is greater than 2 % of the maximum current (r0209) of the infeed to provide
protection against short-circuit in the DC link.
- if a Voltage Sensing Module (VSM) is being used, the line supply voltage amplitude is greater than 3 % of the
parameterized unit supply voltage (p0210) to protect the precharging resistors against continuous filter current when
the line supply partially returns.
Dependency:
Refer to: r0209, p0210, r1214
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Speed control activated
Fast flying restart w/ voltage model for
induction motor activ.
Fast flying restart w/ voltage model for
induction motor exited
Apply VSM voltage to the monitor
Preassign flux ramp
Adaptation current controller and speed
adapt. controller gain
Voltage pulse active
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
-
-
-
-
-
-
-