Siemens G130 List Manual page 608

Hide thumbs Also See for G130:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p3513
BI: Voltage-controlled operation inhibit / U_ctrl op inhib
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for disabling DC link voltage control on the motor side.
r3517
CO: DC link controller active current setpoint / Vdc I_act set
VECTOR_G
Can be changed: -
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [Arms]
Description:
Display and connector output for the unlimited setpoint of the active current controller of the DC link voltage control
on the motor side.
p3519[0...3]
CI: DC link pre-control power (scaled) / Vdc prectrl P scal
VECTOR_G
Can be changed: T
(Tech_ctrl)
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Sets the signal source for power pre-control.
Dependency:
Refer to: p3521
Note:
Closed-loop control of the DC link voltage is improved by pre-controlling the power required for the other
components.
A scaled quantity is expected so that the various power reference values (r2004) of the drive objects must be taken
into account. The scaling factors are used to adapt the scaling (p3521).
p3520[0...3]
CI: DC link pre-control power (not scaled) / Vdc pre-ctrl P
VECTOR_G
Can be changed: T
(Tech_ctrl)
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Sets the signal source for power pre-control.
Dependency:
Refer to: p3521
Note:
Closed-loop control of the DC link voltage is improved by pre-controlling the power required for the other modules.
A non-scaled quantity is expected so that the various power reference values (r2004) of the drive objects do not have
to be taken into account. The scaling factors are used to adapt the scaling (p3521).
608
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: r2004
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 7960
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 6220, 7960
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 7960
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SinamicsG150

Table of Contents