p0824[0...n]
BI: Drive Data Set selection DDS bit 4 / DDS select., bit 4
VECTOR_G
Can be changed: C2(15), T
Data type: Unsigned32 / Binary
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the signal source to select the Drive Data Set, bit 4 (DDS, bit 4).
Dependency:
Refer to: r0051, r0837
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p0826[0...n]
Motor changeover motor number / Mot_chng mot No.
VECTOR_G
Can be changed: C2(3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the freely assignable motor number for the motor changeover.
Dependency:
Refer to: p0827
Notice:
When changing over motor data sets with the same motor number (e.g. star-delta changeover) and for a motor with
brake, the motor brake remains open during the changeover.
Note:
When the motor data sets are changed over, the following applies:
The same motor number signifies the same thermal model.
For the same motor number, the correction values of the Rs, Lh or kT adaptation are applied for the data set
changeover (refer to r1782, r1787, r1797).
p0827[0...n]
Motor changeover status word bit number / Mot_chg ZSW bitNo.
VECTOR_G
Can be changed: C2(3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the bit number for every motor data set.
Example:
p0827[0] = 0: For MDS0, r0830.0 is switched.
p0827[1] = 5: For MDS1, r0830.5 is switched.
Dependency:
Refer to: p0826, r0830
Note:
A motor is only changed over (a new motor selected) after the pulses have been suppressed.
When the motor data sets are changed over, the following applies:
Bit numbers that are not identical, signify that the motor must be changed over.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
15
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
15
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8565, 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0
269